|  | 3MU/FRD6006 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation duct. Max duct size 13 in. diameter., 26 gauge steel. 1 Layer of 3M Fire Barrier Duct Wrap 15A or Fire Barrier Duct Wrap 615 per ISO6944 for 1 hour protection. Formerly VAD545F. |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |
|  | 3MU/FRD6005 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation duct. Max duct size 21 in. diameter., 24 gauge steel. 1 Layer of 3M Fire Barrier Duct Wrap 15A or Fire Barrier Duct Wrap 615 per ISO6944 for 1 hour protection. Formerly VAD544F. |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |
|  | 3MU/FRD6004 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation duct. Max duct size 40 in. diameter., 20 gauge steel. 1 Layer of 3M Fire Barrier Duct Wrap 15A or Fire Barrier Duct Wrap 615 per ISO6944 for 1 hour protection. Formerly VAD543F. |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |
|  | 3MU/FRD12004 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation Duct. Max duct size 40 in. diameter, 20 gauge steel. 2 Layers of 3M Fire Barrier Duct Wrap 15A or 1 layer of Fire Barrier Duct Wrap 615 per ISO6944 for 2 hour protection. Formerly VAD542F. |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |
|  | 3MU/FRD6003 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation duct. Max duct size 12 in.x 12 in., 26 gauge steel. 1 Layer of 3M Fire Barrier Duct Wrap 15A or Fire Barrier Duct Wrap 615 per ISO6944 for 1 hour protection. Formerly VAD536F. |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |
|  | 3MU/FRD6002 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation duct. Max duct size 40 in. x 10 in., 24 gauge steel. 1 Layer of 3M Fire Barrier Duct Wrap 15A or Fire Barrier Duct Wrap 615 per ISO6944 for 1 hour protection. Formerly VAD535F. |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |
|  | 3MU/FRD6001 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation duct. Max duct size 60 in. x 24 in., 20 gauge steel. 1 Layer of 3M Fire Barrier Duct Wrap 15A or Fire Barrier Duct Wrap 615 per ISO6944 for 1 hour protection. Formerly VAD534F. |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |
|  | 3MU/FRD12003 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation Duct. Max duct size 12 in. x 12 in., 26 gauge steel. 2 Layers of 3M Fire Barrier Duct Wrap 15A or 1 layer of Fire Barrier Duct Wrap 615 per ISO6944 for 2 hour protection. Formerly VAD531F. |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |
|  | 3MU/FRD12002 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation Duct. Max duct size 40 in. x 10 in., 24 gauge steel. 2 Layers of 3M Fire Barrier Duct Wrap 15A or 1 layer of Fire Barrier Duct Wrap 615 per ISO6944 for 2 hour protection. Formerly VAD530F |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |
|  | 3MU/FRD12001 Date Posted: 10/26/2009 Changed Content : Added Fire Barrier Duct Wrap 615 Ventilation Duct. Max duct size 60 in. x 24 in., 20 gauge steel. 2 Layers of 3M Fire Barrier Duct Wrap 15A or 1 layer of Fire Barrier Duct Wrap 615 per ISO6944 for 2 hour protection. Formerly VAD529F |
| |  | 3M(TM) Fire Barrier Duct Wrap 15A |
 |
| |  | 3M(TM) Fire Barrier Duct Wrap 615 |
 |